MOLA Electronics Box Input Test Specification

X-direction Input

Following are the X-direction test specification input levels that were derived from the analytical responses. The table gives the values that are plotted in the chart. Recall that the Grms value is the area under the curve and represents the root mean square value of the acceleration.

Electroncis Box Random Spec for X
FREQ(Hz)ASD(G2/Hz)dB/OCTGrms
20.000.02500.000.00
140.001.00005.716.94
165.001.00000.008.55
200.000.2500-21.699.58
250.000.25000.0010.21
300.001.000022.8911.48
350.001.00000.0013.48
500.000.1000-19.4315.39
2000.000.0250-3.0117.50


On to the Electronics Box Y-direction Test Input Page.
Back to the Electronics Box Results Page.
Back to the MOLA Random Vibration Page.
Back to the MOLA Mechanical Analysis Page.

This page is maintained by Ryan Simmons , at Ryan.Simmons@nasa.gov.
This page was last updated on {{DATE}}.