MOLA Electronics Box Input Test Specification

Y-direction Input

Following are the Y-direction test specification input levels that were derived from the analytical responses. The table gives the values that are plotted in the chart.

Electroncis Box Random Spec for Y
FREQ(Hz)ASD(G2/Hz)dB/OCTGrms
20.000.02500.000.00
130.000.75005.475.87
180.000.75000.008.48
260.000.1500-13.1810.02
290.000.15000.0010.24
330.000.350019.7410.70
380.000.35000.0011.48
420.000.1500-25.4811.89
550.000.15000.0012.68
670.000.750024.5514.38
760.000.75000.0016.56
2000.000.0025-17.7519.74


On to the Electronics Box Z-direction Test Input Page.