MOLA Titanium Support Tube Input Test Specification

Z-direction Input

Following are the Z-direction test specification input levels that were derived from the analytical responses. The table gives the values that are plotted in the chart.

Titanium Support Tube Input Spec for Z
FREQ(Hz)ASD(G2/Hz)dB/OCTGrms
20.000.01000.000.00
95.001.50009.685.81
120.001.50000.008.44
200.000.0400-21.369.97
500.000.04000.0010.56
2000.000.0100-3.0111.80


Back to the Titanium Support Tube Results Page.